MODEL |
Specifications (DLS-1500L) |
Laser Type |
Laser Type: Wavelength 905 nm Infrared
Optic Type: Low-Gain-APD Laser Diode
Eye Safety: Class 1, (7mm, FDA CFR21)
Beam Divergence: 3 milliradians (~ 0.3 m @ 100 m)
|
Measuring range (Max) |
150M with 10% Gray Wall Targets
450M with White Wall Targets
1700M with Prism(Diamond Grade) Reflector
|
Measuring Quality |
Resolution: 1 [mm]
Accuracy: ¡¾1[cm] @0~150M, ¡¾2[cm] @150~1500M
|
Input/Output and
Communications
|
Power Input: 24VDC ( 2.0A/Max )
Data Interface:
- Serial RS-232 and RS-485
Analog output: 4-20 mA Current
Network Interface (Optional) :
- Ethernet TCP/IP 10/100Mbps
- Remote Configure and Monitoring
|
Environmental |
Operating Temperature: -20 to +60 [¡ÆC]
Humidity: 20% to 80% relative humidity
|
Enclosure Housing |
200 x 450 x 150 [mm]
SUS Outdoor / Dust proven
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Multiple
Smart Sensor Network
Controller
Multiple Configure
Multiple Monitoring
Multiple DATA Backup
|
|
MODEL |
DLS-1500NET |
TYPE |
MULTIPLE LASER SENSOR CONTROLLER
(Smart Network Sensor Controller)
|
Input Port |
Serial: RS-485 x 8-Ports
(4~20mA Current Signal DATA)
|
Output Port |
Network: Ethernet 10/100Mbps RJ45
Serial: RS-485 x 8-Ports
(4~20mA Current Signal DATA)
|
Power Input |
24VDC(2.5A/max)
|
Functions |
Multiple Sensor Control via Single TCP/IP
- Point to Point Configuration
- Point to Multi-Point Configuration
- Point to Multi-Point Monitoring
Multiple Sensor to PLC TCP/IP Transmission Support
PLC I/F Support: SIEMENS, YASKAWA, MELSEC, ¡¦
Management Program: Microsoft Windows XP/7/8.x
- Multiple Sensor Configure and Monitoring
- Multiple Sensor DATA Logging and GUI Viewer
|
Dimension |
230(W)X300(H)X45(D)mm
|
|
|
|
|
|
|
|